10 temporary Pacing questions from the ICU Basics bank. Tap an answer to see whether you were right, with a rationale for every choice. Your score is at the end.
After valve surgery, a patient in complete heart block is paced VVI at 80 with BP 82/50. After a change to DDD at the same rate with atrial and ventricular wires, the BP rises to 112/68. What BEST explains the improvement?
DDD delivers higher energy to the ventricle
VVI pacing was failing to capture the ventricle
DDD restored AV synchrony and the atrial kick
DDD mode increases the maximum paced rate
Show the answer and rationale
Answer: C
A. Output is set independently of the mode.
B. Capture was present in VVI. The difference is the timing of atrial and ventricular contraction.
C.Correct. Sequential atrial and ventricular pacing restores the atrial contribution to filling, raising stroke volume.
D. The rate was unchanged.
In VVI pacing with complete heart block, atria and ventricles contract independently, so atrial contraction may occur against closed AV valves, reducing filling and causing pacemaker syndrome (hypotension, cannon A waves). DDD senses and paces both chambers in sequence, preserving the atrial kick (about 20–30% of ventricular filling), which matters most in stiff, hypertrophied, or post-surgical ventricles. By convention, atrial epicardial wires exit to the right of the sternum and ventricular wires to the left.
On postoperative day 2 after CABG, a patient has a new regular tachycardia with sawtooth waves in leads II, III and aVF. The patient is alert without chest pain, and atrial and ventricular epicardial wires are in place. Which intervention should the nurse prepare for FIRST? Data are:
HR 150/min, regular
Atrial rate 300/min
BP 114/70 mm Hg
SpO₂ 96% on 2 L/min
K⁺ 4.4 mEq/L
rapid atrial pacing through the atrial wires.
synchronized cardioversion at 50 J.
IV adenosine 6 mg by rapid push.
IV amiodarone 150 mg over 10 minutes.
Show the answer and rationale
Answer: A
A.Correct. Short bursts of atrial pacing faster than the flutter rate can capture and end the flutter circuit at the bedside without sedation.
B. Cardioversion converts flutter well, but it needs sedation and is the first choice when the patient is unstable; this patient is stable and has wires.
C. Adenosine briefly blocks the AV node and can unmask flutter waves, but it does not end the atrial re-entry circuit.
D. Amiodarone is a reasonable drug for stable flutter, but it acts slowly and adds hypotension and bradycardia when a faster, drug-free option is available.
An atrial rate of 300/min with a ventricular rate of 150/min is atrial flutter with 2:1 conduction. Because the patient is stable and still has atrial epicardial wires, the team can try rapid atrial pacing: the atria are paced in bursts of up to about 20 seconds at 20 to 30 beats/min faster than the flutter rate, which captures the re-entrant circuit, so sinus rhythm returns as soon as pacing stops if it worked. It avoids sedation and drug side effects, but it does not convert atrial fibrillation. Synchronized cardioversion is the choice for hemodynamic instability, and antiarrhythmics such as amiodarone are the pharmacologic route in stable patients.
On the first day after AVR, a patient's epicardial ventricular wires are connected to a temporary pacemaker set to VVI at 70/min, output 10 mA and sensitivity 6 mV. Sinus rhythm has returned at 84/min. The nurse sees pacer spikes landing inside native QRS complexes and on some T waves, and the patient is alert without symptoms.
Data are:
BP 118/64 mm Hg
HR 84/min
K 4.2 mEq/L
Mg 2.1 mg/dL
Which adjustment is MOST appropriate?
raise the sensitivity setting to 10 mV.
change the mode to VOO at 70/min.
lower the sensitivity setting to 2 mV.
increase the output to 20 mA.
Show the answer and rationale
Answer: C
A. A higher mV number makes the pacemaker less sensitive, so it would miss even more native beats; this is the fix for oversensing, not undersensing.
B. Asynchronous pacing ignores all native beats, which creates the very competition seen on the strip and raises the risk of R-on-T VF.
C.Correct. Spikes that ignore native beats are undersensing; a lower mV number makes the pacemaker see smaller signals, so it is inhibited by the patient's own QRS.
D. Output fixes failure to capture. Here the problem is that the device does not see the native QRS, and higher output makes a spike on the T wave more dangerous.
Sensitivity on a temporary pacemaker is set in millivolts and works like a fence: the lower the number, the smaller the signal the device will recognize. Epicardial ventricular signals after valve surgery can be small, so a 6 mV setting may miss them, and the pacemaker then fires on its timer regardless of the patient's rhythm. A spike that falls on the T wave can trigger VF, so undersensing is corrected promptly by lowering the mV value (commonly to about 2 mV for the ventricle) and confirming that native beats inhibit the device. Capture and sensing thresholds are rechecked daily because they drift.
Four days after AVR, the patient is scheduled for transfer to the step-down unit, and an order reads "Remove epicardial pacing wires this morning." The temporary pacemaker is set to VVI 60/min as a backup. Overnight telemetry shows several runs of complete heart block during which the pacemaker took over.
Data are:
BP 118/66 mm Hg
HR 72/min, sinus with first-degree AV block
Underlying rhythm during block: ventricular escape 34/min
Paced beats: 30% over 24 hours
INR 1.3
Which action SHOULD the nurse take FIRST?
Turn the pacemaker off for 4 hours to test whether it is needed
Remove the wires and place transcutaneous pads for 24 hours
Hold the removal and report the intermittent block to the surgeon
Remove the wires, then keep the patient on bed rest for 1 hour
Show the answer and rationale
Answer: C
A. A trial off pacing would leave the patient with an escape rate of 34/min during the next run of block, which risks syncope or arrest.
B. Pads are a reasonable backup, but transcutaneous pacing is painful and less reliable, and removing working wires from a patient who still needs them adds risk for no gain.
C.Correct. Recurrent complete block with a 34/min escape means the patient still depends on the backup pacing, so the wires stay until conduction recovers or a permanent device is placed.
D. Bed rest and vital sign checks are standard after wire removal because of tamponade risk, but the problem here is that the wires are still needed.
Conduction tissue sits close to the aortic annulus, so edema, sutures and debridement during AVR can cause transient or permanent AV block. Epicardial wires are removed only when the patient no longer needs them. Runs of complete heart block with a slow ventricular escape on day 4 mean the patient is still pacing dependent, so the nurse questions the removal order and reports the telemetry findings. The team will then decide whether to wait for recovery or arrange a permanent pacemaker. When removal does happen later, it is done with an acceptable INR, followed by bed rest, frequent vital signs and watching for tamponade.
Six hours after transcatheter aortic valve replacement (TAVR), a patient on telemetry develops a new left bundle branch block and the heart rate drops to 44 with a PR interval of 0.28 seconds. The temporary transvenous pacing wire placed during the procedure is still in place. The patient is dizzy. Which action is MOST appropriate?
Document the finding as an expected change after valve replacement
Give atropine 1 mg IV and reassess the rate and symptoms in 5 minutes
Obtain a 12-lead ECG and recheck the rhythm in 1 hour
Confirm the pacing wire is capturing and set a backup rate
Show the answer and rationale
Answer: D
A. New LBBB is common after TAVR, but with bradycardia and symptoms it is not benign and needs action.
B. Atropine works at the AV node and has little effect on infranodal conduction disease caused by the valve compressing the conduction system.
C. A 12-lead ECG documents the new block, but waiting an hour in a dizzy patient with a rate of 44 risks sudden progression to complete heart block. The pacing wire that is already in place should be used now.
D.Correct. New LBBB with bradycardia after TAVR signals conduction injury that can progress to complete heart block; backup pacing is the safeguard.
The aortic valve annulus sits next to the bundle of His and left bundle. A TAVR prosthesis can compress this tissue, producing new LBBB, PR prolongation, and complete heart block, sometimes days later. Atropine acts at the AV node and is often ineffective for this infranodal block. Symptomatic bradycardia after TAVR is managed with temporary pacing, and persistent high-grade block leads to permanent pacemaker placement.
A patient with an acquired long QT has recurrent pause-dependent torsades de pointes despite IV magnesium. Temporary overdrive pacing is ordered. How does this therapy prevent recurrences?
It turns off the sinus node so the heart can recover
It paces faster, shortening QT and preventing pauses
It paces the atria and ventricles at the same instant
It delivers a synchronized shock through the pacing wire
Show the answer and rationale
Answer: B
A. Overdrive pacing takes over the rhythm. It does not suppress the sinus node permanently.
B.Correct. Pacing at about 90–110 eliminates the pauses that trigger torsades and shortens repolarization.
C. Simultaneous pacing does not suppress torsades.
D. Pacing wires deliver milliamp-level stimuli, not cardioversion shocks.
Torsades de pointes associated with QT prolongation is often pause-dependent: a long pause followed by a premature beat triggers it. Increasing the heart rate by overdrive pacing (or isoproterenol if pacing is unavailable and there is no ischemia) shortens the QT and eliminates pauses. Additional treatment includes IV magnesium, potassium repletion to about 4.5–5, stopping QT-prolonging drugs, and defibrillation for sustained torsades.
A temporary transvenous pacemaker is set to VVI at 60/min. The patient’s underlying rhythm is sinus at 72/min with a normal PR interval and a narrow QRS. What should the nurse expect to see on the monitor?
Atrial pacing spikes preceding each P wave
Ventricular pacing spikes at 60/min between native beats
Native sinus rhythm with no pacing spikes
A pacing spike after each P wave to track the atrium
Show the answer and rationale
Answer: C
A. VVI mode paces only the ventricle.
B. In VVI mode, sensed native beats above the set rate inhibit pacing, so no spikes should appear.
C.Correct. The pacemaker senses each native QRS and inhibits its output because the intrinsic rate exceeds 60.
D. Atrial tracking (triggered response) occurs in DDD or VDD modes, not VVI.
The NBG code for VVI is: V (ventricle paced), V (ventricle sensed), I (inhibited response). The pacemaker fires only when no intrinsic ventricular beat occurs within the set interval (1,000 ms at 60/min). With a native rate of 72, every beat is sensed and pacing is inhibited, so no spikes appear. To confirm the backup works, the nurse checks the capture and sensing thresholds per protocol.
On the morning after CABG ×2, a patient's epicardial ventricular wires are connected to a temporary pacemaker set to VVI at 60/min, output 8 mA and sensitivity 2 mV. Capture and sensing were confirmed at the start of the shift.
Data are:
0600: underlying sinus rate 48/min; ventricular paced rhythm at 60/min
0800: sinus rhythm 72/min, PR 0.18 seconds, QRS 0.08 seconds
What SHOULD the nurse expect to see on the monitor at 0800?
ventricular spikes at 60/min between sinus beats.
paced ventricular beats at 60/min with P waves marching through.
sinus beats with no pacer spikes.
a ventricular spike after each P wave at 72/min.
Show the answer and rationale
Answer: C
A. This describes asynchronous (VOO) pacing or undersensing. A properly sensing VVI pacemaker does not fire while native beats arrive faster than its lower rate.
B. That was the 0600 picture, when the sinus rate of 48/min was below the lower rate. Once the sinus rate exceeds 60/min, pacing stops.
C.Correct. In VVI mode, each sensed native QRS resets the timer; with the sinus rate at 72/min, above the lower rate of 60/min, the pacemaker stays inhibited.
D. Tracking the atrium and pacing the ventricle after each P wave is DDD or VDD behavior; a VVI pacemaker has no atrial sensing.
VVI means the ventricle is paced, the ventricle is sensed, and a sensed beat inhibits the next pacing pulse. The pacemaker fires only when no native QRS appears within the interval set by the lower rate (1 second at 60/min). At 0600 the sinus rate was slower than that, so the device paced the ventricle and the P waves ran independently. By 0800 the sinus rate has risen to 72/min with normal conduction, so the device stays silent. Seeing no spikes is expected, not a malfunction, and the wires stay connected as backup until the team decides they are no longer needed.
Six hours after mitral valve repair, a patient develops a regular narrow-complex tachycardia. P waves cannot be identified on any surface lead, and atrial epicardial wires are in place. Which action will BEST clarify the rhythm? Data are:
HR 140/min, regular
BP 104/62 mm Hg
CVP 11 mm Hg
Temperature 37.4°C
Mg²⁺ 2.0 mg/dL
give IV metoprolol 5 mg to slow the rate.
perform carotid sinus massage at the bedside.
record an atrial electrogram from the wires.
request a transthoracic echocardiogram.
Show the answer and rationale
Answer: C
A. Slowing the rate may help later, but treating before the rhythm is known can drop the BP and leaves the diagnosis unclear.
B. A vagal maneuver can slow AV conduction and expose atrial activity, but it is less reliable and riskier after surgery than reading the signal from wires already in place.
C.Correct. The atrial wire records large atrial signals, so the atrial rate and its ratio to the ventricular rate become visible and the rhythm can be named.
D. Echo is useful for tamponade or valve function after repair, but it does not show the atrial electrical activity needed to name the rhythm.
Small atrial signals on surface leads often hide P waves after cardiac surgery, and atypical flutter is common in patients with surgical atrial scars. An atrial electrogram, made by connecting the atrial epicardial wire to an ECG lead (or a bedside adapter), magnifies the atrial signal. The ratio of atrial to ventricular signals then sorts the rhythm: 2:1 or variable ratios point to flutter or atrial tachycardia, a 1:1 ratio with normal sequence suggests sinus tachycardia, chaotic atrial signals mean atrial fibrillation, and simultaneous or retrograde atrial signals suggest a junctional or AV nodal re-entry rhythm. Treatment choices, including rapid atrial pacing, depend on that diagnosis.
On postoperative day 2 after CABG ×3, the patient develops a regular narrow-complex tachycardia. An atrial electrogram recorded through the atrial epicardial wires shows regular atrial activity at 300/min with 2:1 conduction. The provider plans rapid atrial pacing.
Data are:
BP 104/62 mm Hg
HR 150/min, regular
MAP 76 mm Hg
K 4.4 mEq/L
Mg 2.0 mg/dL
Which setup SHOULD the nurse anticipate?
Ventricular wires, pacing at about 330/min for 15 to 30 seconds
Atrial wires, pacing at about 160/min for 15 to 30 seconds
Atrial wires, pacing at 100/min for 2 minutes
Atrial wires, pacing at about 330/min for 15 to 30 seconds
Show the answer and rationale
Answer: D
A. This rate applied to the ventricle would likely cause ventricular fibrillation; confirming which wires are atrial is a key safety step.
B. 160/min is faster than the ventricular rate on the monitor, but the flutter circuit runs at 300/min; pacing below the atrial rate cannot capture and interrupt it.
C. Pacing below the flutter rate cannot enter and interrupt the circuit, so the flutter continues.
D.Correct. Pacing the atrium slightly faster than the flutter rate captures the circuit; when pacing stops abruptly, sinus rhythm often resumes.
Typical atrial flutter is a macro-reentrant circuit in the right atrium with an atrial rate near 300/min, often conducted 2:1 to give a regular ventricular rate of about 150/min. An atrial electrogram from the epicardial wires shows the flutter waves clearly. Rapid atrial pacing, started somewhat faster than the atrial rate (about 10 to 20 percent) for 15 to 30 seconds at a high output and then stopped abruptly, can capture and terminate the circuit. Only a pacemaker with a rapid atrial pacing function and the atrial wires are used, so the nurse confirms wire labels before pacing starts and keeps a defibrillator ready. Pacing may also convert flutter to atrial fibrillation, which is easier to rate-control.
These 10 are a sample. ICU Basics has 46 temporary Pacing questions, and it keeps your score, explains every choice and brings back the ones you miss. No ads. Pro is coming in January 2027.