Laboratory Math
Antigen-Negative Units to Screen Calculator
How many donor units to test to find enough that lack one, two or three antigens, from each antigen’s frequency.
Formula
Fraction negative = (1 − f₁) × (1 − f₂) × … (f = fraction of donors positive)
Units to screen = units needed ÷ fraction negative, rounded up
How it is used
- Use the antigen frequencies for your donor population; they differ by ancestry (for example Fy(a−b−) is common in donors of African ancestry and rare in donors of European ancestry).
- The answer is an average: you may need to screen more. The crossmatch is still required for a clinically significant antibody.
Related calculators
- Beer's Law: Unknown Concentration and Absorbance
- Centrifuge: RPM and Relative Centrifugal Force (× g)
- Conventional and SI Units
- Dilution Factor, Serial Dilutions and Corrected Result
- eGFR (CKD-EPI 2021, Creatinine)
- Fetal-Maternal Hemorrhage (Kleihauer-Betke) and RhIG Vials
- LDL Cholesterol (Friedewald) and Non-HDL
- Manual Cell Count (Hemocytometer)
Practice in your browser4,850+ exam-style questions with rationales. No ads. Pro is coming in January 2027. Also on the App Store and Google Play.
For education and exam preparation only. Follow your institution’s protocols. For education and exam preparation only. Verify results independently and follow your institution’s protocols. Not a substitute for clinical judgment.