Laboratory Math
Dilution Factor, Serial Dilutions and Corrected Result Calculator
The dilution of each tube and of the whole series, and a diluted result multiplied back to the patient value.
Formula
Dilution factor of one tube = (sample + diluent) ÷ sample
Series: tube n = (one-tube factor)ⁿ
Patient result = result read × total dilution factor
How it is used
- A twofold series (equal volumes of sample and diluent each step) runs 1:2, 1:4, 1:8, 1:16. The titer is the reciprocal of the highest dilution still positive.
- A fourfold (two-tube) change in titer between acute and convalescent sera is the usual mark of a significant antibody rise.
- When a result is above the linear range, dilute, rerun and multiply; check that the diluted result falls inside the reportable range.
Related calculators
- Antigen-Negative Units to Screen
- Beer's Law: Unknown Concentration and Absorbance
- Centrifuge: RPM and Relative Centrifugal Force (× g)
- Conventional and SI Units
- eGFR (CKD-EPI 2021, Creatinine)
- Fetal-Maternal Hemorrhage (Kleihauer-Betke) and RhIG Vials
- LDL Cholesterol (Friedewald) and Non-HDL
- Manual Cell Count (Hemocytometer)
Practice in your browser4,850+ exam-style questions with rationales. No ads. Pro is coming in January 2027. Also on the App Store and Google Play.
For education and exam preparation only. Follow your institution’s protocols. For education and exam preparation only. Verify results independently and follow your institution’s protocols. Not a substitute for clinical judgment.