Dead Space Fraction (Bohr) Calculator
Share of each breath that is wasted ventilation, from PaCO2 and end-tidal CO2; rises with PE and overdistension.
Formula
((PaCO2 - PetCO2) / PaCO2) * 100
Reference: PaCO₂–EtCO₂ gap normally 2–5 mmHg
How it is used
- This is the alveolar dead-space fraction, (PaCO₂ − EtCO₂) ÷ PaCO₂, a bedside stand-in for the Enghoff VD/VT, which uses mixed expired CO₂.
- The PaCO₂–EtCO₂ gap is normally 2–5 mm Hg and widens with dead space: pulmonary embolism, low cardiac output, overdistension or auto-PEEP.
- In ARDS a higher dead-space fraction carried a higher risk of death: about 45% higher odds for each 0.05 rise in VD/VT (Nuckton 2002).
Related one-pagers
- ABG Interpretation in 6 StepsAbove the knee, large PaO₂ changes barely move saturation; below it, saturation falls steeply. A right shift lowers affinity and unloads O₂ to tissue: acidosis (the Bohr effect), hypercapnia, fever, raised 2,3-DPG (chronic hypoxemia, anemia, altitude). A left shift holds O₂: alkalosis, hypothermia, low 2,3-DPG (banked blood), CO, methemoglobin, fetal hemoglobin.
- CapnographyThe Bohr equation gives the dead-space fraction: VD/VT = (PACO₂ − PĒCO₂) ÷ PACO₂, where PĒCO₂ is mixed expired CO₂ collected over a minute or measured by volumetric capnography. Enghoff substituted PaCO₂ for the alveolar value, VD/VT = (PaCO₂ − PĒCO₂) ÷ PaCO₂, which is what bedside calculation uses. Because PaCO₂ also carries the effect of shunt and V/Q mismatch, Enghoff dead space is larger than true Bohr dead space. Normal VD/VT is about 0.3 breathing spontaneously; equipment adds to it on the ventilator.
- Ventilator Modes and Settings
Related calculators
- A-a Gradient
- Alveolar Gas Equation (PAO₂)
- Arterial Oxygen Content (CaO₂)
- Driving Pressure
- Dynamic Compliance
- Minute Ventilation
- O₂ Extraction Ratio
- Oxygen Consumption (VO₂)
Practice free in your browser3,800+ exam-style questions with rationales. No account, no ads. Also free on the App Store and Google Play.
For education and exam preparation only. Follow your institution’s protocols. For education and exam preparation only. Verify results independently and follow your institution’s protocols. Not a substitute for clinical judgment.