Practice questions

Hemodynamics practice questions

10 hemodynamics questions from the ICU Basics bank. Tap an answer to see whether you were right, with a rationale for every choice. Your score is at the end.

Questions reviewed by Alex G, BSN, RN, CEN, CCRN, CMC, NREMT-P · From the live ICU Basics bank · Study first: Hemodynamic Normals cheat sheet

Question 1 · Hemodynamics

A patient’s arterial line reads 124/62 mm Hg (MAP 82). The bed is then raised to working height, but the pole-mounted transducer is not moved, leaving it 10 cm below the phlebostatic axis. The monitor now reads 132/70 mm Hg (MAP 90). The nurse recognizes that the patient’s TRUE MAP is closest to:

  1. 80 mm Hg, because each 1 cm of error equals 1 mm Hg
  2. 97 mm Hg, because a low transducer reads falsely low
  3. 90 mm Hg, because height changes only the waveform shape
  4. 83 mm Hg, because the reading is falsely high by about 7
Show the answer and rationale

Answer: D

  • A. A 1 cm error equals about 0.74 mm Hg, not 1 mm Hg.
  • B. The direction is reversed. A transducer below the heart reads falsely high.
  • C. Height changes the hydrostatic pressure on the transducer, which shifts every numeric value.
  • D. Correct. 10 cm H₂O ≈ 7.4 mm Hg of added hydrostatic pressure, so the displayed MAP of 90 overestimates the true MAP by about 7 mm Hg.

The transducer must be leveled at the phlebostatic axis (4th intercostal space, mid-anterior-posterior diameter). Every 1 cm of height difference introduces about 0.74 mm Hg of error, because 1.36 cm H₂O = 1 mm Hg. A transducer placed below the axis bears the extra weight of the fluid column and reads falsely high, and one placed above reads falsely low. The error is small for arterial pressures but clinically large for CVP and PAOP, so the transducer should be re-leveled whenever the bed height or patient position changes.

Sources: AACN Procedure Manual, 8th ed.; Saugel et al., Crit Care (2020)

Question 2 · Hemodynamics

On the first night after CABG ×3, a patient's pressure transducer is mounted on an IV pole and was leveled with the head of the bed flat. At 0300 the head of the bed is raised to 30 degrees for comfort, and the pole is not adjusted. Data are: 0200 (flat): CVP 9 mm Hg, PAOP 12 mm Hg 0330 (30 degrees): CVP 15 mm Hg, PAOP 18 mm Hg HR 82/min and urine output 60 mL/hr at both times Which action is MOST appropriate?

  1. anticipate furosemide for rising filling pressures.
  2. lower the head of the bed flat for each reading.
  3. level the transducer to the phlebostatic axis.
  4. re-zero the transducer to atmospheric pressure.
Show the answer and rationale

Answer: C

  • A. Both pressures rose by exactly the same amount right after a position change, with no change in HR or urine output, which points to artifact rather than volume overload.
  • B. Readings are accurate with the head of the bed from 0 to 60 degrees in the supine position once the transducer is leveled, so lying the patient flat is unnecessary.
  • C. Correct. Raising the head of the bed moved the phlebostatic axis above the fixed transducer, which adds a hydrostatic column and reads falsely high; re-leveling at the 4th intercostal space, mid-chest, corrects it.
  • D. Zeroing removes atmospheric pressure from the reading but does not correct a height difference between the transducer and the heart, which is the error here.

Hemodynamic pressures are referenced to the phlebostatic axis, the 4th intercostal space at half the anteroposterior chest diameter, which approximates the atria. Every centimeter the transducer sits below that point adds about 0.74 mm Hg to the reading, and every centimeter above it subtracts the same. When the head of the bed is raised and the pole-mounted transducer stays put, the chest rises above it and the readings jump artificially, as both pressures did here by 6 mm Hg. AACN guidance supports readings from flat up to 60 degrees supine if the transducer is re-leveled after each position change, and zeroing is a separate step.

Sources: AACN Practice Alert: PA/CVP Monitoring (2016); AACN Procedure Manual, 8th ed.

Question 3 · Hemodynamics

A 61-year-old patient with severe COPD and hypoxemia has a PA catheter in the cardiac ICU. Data are: PA 52/30 mm Hg, PAOP 12 mm Hg, RAP 15 mm Hg, CI 2.1 L/min/m². To reduce balloon inflations, a resident suggests trending the PA diastolic pressure in place of the PAOP. Which response is BEST?

  1. PAD will overestimate PAOP here; keep measuring the wedge
  2. Trend PAD, subtracting a fixed 2 mm Hg from each reading
  3. PAD is a reliable substitute in most patients with COPD
  4. Trend the RAP instead, because it equals PAOP in lung disease
Show the answer and rationale

Answer: A

  • A. Correct. The PAD exceeds the PAOP by 18 mm Hg; a gradient this wide reflects high pulmonary vascular resistance, so the PAD no longer tracks left-sided filling pressure.
  • B. A fixed correction assumes a small, stable gradient. Here the gradient is 18 mm Hg and can change with oxygenation, so any fixed offset misleads.
  • C. PAD tracks PAOP only when pulmonary vascular resistance is normal, with a diastolic gradient under about 7 mm Hg. Hypoxic vasoconstriction in COPD widens the gradient, as these numbers show.
  • D. Lung disease raises right-sided pressures independently of the left heart, so the RAP of 15 mm Hg is higher than the PAOP and cannot stand in for it.

The PA diastolic pressure normally runs within a few mm Hg of the PAOP because, at end-diastole, there is little flow across a normal pulmonary vascular bed. When pulmonary vascular resistance rises from hypoxia, COPD, pulmonary embolism, or pulmonary arterial hypertension, the PAD climbs well above the PAOP; a diastolic pulmonary gradient (PAD minus PAOP) of 7 mm Hg or more means the PAD overstates left-sided filling. In that situation the intermittent wedge reading, taken at end-expiration when pericardial pressure is lowest, remains the measure to follow.

Sources: Bootsma et al., PA Catheter Part 1 (2022); Gilbert-Kawai et al., PA Catheterisation, BJA Educ (2024)

Question 4 · Hemodynamics

PAOP is used to estimate LV end-diastolic pressure (LVEDP). In which patient is PAOP MOST likely to OVERESTIMATE the true LVEDP?

  1. A patient with acute severe aortic regurgitation
  2. A patient with severe mitral stenosis
  3. A patient with a stiff, hypertrophied LV
  4. A patient with hypovolemia and normal valves
Show the answer and rationale

Answer: B

  • A. In acute AR, LV pressure rises rapidly and may close the mitral valve early, so PAOP underestimates LVEDP.
  • B. Correct. The gradient across the stenotic valve means left atrial pressure (and PAOP) exceeds LVEDP.
  • C. With a noncompliant LV, the atrial contribution raises LVEDP above the mean PAOP, so PAOP tends to underestimate it.
  • D. With normal valves and no PEEP effects, PAOP approximates LVEDP.

PAOP reflects left atrial pressure, which approximates LVEDP only when the pathway from the catheter tip to the LV is unobstructed. PAOP overestimates LVEDP with mitral stenosis, mitral regurgitation (large v waves), high PEEP or a catheter tip outside zone 3, pulmonary venous obstruction, and tachycardia. It underestimates LVEDP with a stiff LV or aortic regurgitation. PAOP should be interpreted in context rather than as a stand-alone number.

Sources: Lough, Hemodynamic Monitoring (2015); Edwards Cardiopulmonary Quick Guide, 4th ed.

Question 5 · Hemodynamics

A spontaneously breathing patient (not ventilated) has a PAOP tracing that falls to 8 mm Hg with each inspiration and returns to 14 mm Hg at the end of each exhalation. The digital display reads 11 mm Hg. Which value SHOULD the nurse record?

  1. 11 mm Hg, the monitor’s digital mean
  2. The peak of the v wave at end-expiration
  3. 8 mm Hg, the lowest point on the tracing
  4. 14 mm Hg, the value just before inspiration
Show the answer and rationale

Answer: D

  • A. Digital displays average across the respiratory cycle and are inaccurate with respiratory variation.
  • B. PAOP is read as the mean of the a wave at end-expiration. The v-wave peak is higher and overestimates it, especially with mitral regurgitation.
  • C. The trough reflects negative intrathoracic pressure during spontaneous inspiration.
  • D. Correct. With spontaneous breathing, inspiration lowers intrathoracic pressure, so end-expiration is the higher point just before the dip.

Hemodynamic pressures are read at end-expiration, when intrathoracic pressure is closest to atmospheric. During spontaneous breathing, inspiration creates negative intrathoracic pressure, so the waveform dips, and the end-expiratory value is the higher point just before the dip. During positive-pressure ventilation, inspiration raises the waveform, so the end-expiratory value is the lower point just before the rise. Values should be read from a graphic strip rather than the digital display.

Sources: AACN Procedure Manual, 8th ed.; AACN Practice Alert: PA/CVP Monitoring (2016); Edwards Cardiopulmonary Quick Guide, 4th ed.

Question 6 · Hemodynamics

Four days after an anterior myocardial infarction, a ventilated patient develops a new loud systolic murmur with a thrill along the left sternal border, and his blood pressure is falling. With the catheter balloon deflated and a pulmonary artery waveform on the distal port, the therapist draws paired samples. Data are: superior vena cava (proximal port) saturation 64%; pulmonary artery (distal port) saturation 81%; SaO₂ 96%. What do these values indicate?

  1. A left-to-right shunt into the right heart
  2. A rise in cardiac output improving oxygen delivery
  3. Septic shock with impaired tissue oxygen extraction
  4. Acute mitral regurgitation from papillary muscle rupture
Show the answer and rationale

Answer: A

  • A. Correct. Saturation normally falls slightly between the vena cava and the pulmonary artery because desaturated coronary sinus blood joins the flow. A step-up of more than 6% (here 17 points) means oxygenated blood is entering the right heart, as with a post-infarction septal rupture.
  • B. Higher output raises venous saturation at every site, so the vena cava sample would rise too. A 17-point gap between two venous sites is not a flow effect, and the falling pressure argues against better delivery.
  • C. Impaired extraction raises SvO₂ and ScvO₂ together; it does not lift the pulmonary artery sample far above the central venous one, and nothing here suggests infection.
  • D. Papillary muscle rupture also causes shock after infarction, but its murmur is apical, it follows inferoposterior infarcts most often, and regurgitation into the left atrium adds no oxygenated blood to the right heart, so there is no step-up.

Paired oximetry along the right heart is the bedside test for an intracardiac left-to-right shunt. The pulmonary artery saturation (SvO₂, normally about 60% to 80%) is usually slightly lower than the central venous saturation, because coronary sinus blood is very desaturated. When oxygenated blood crosses from the left side, the pulmonary artery sample rises above the vena cava sample; a step-up of more than 6% suggests a shunt, and an SvO₂ above 75% in a shocked patient should raise the question. After infarction, a sudden loud systolic murmur and thrill at the left sternal border with a right-sided oxygen step-up points to interventricular septal rupture, which Doppler echocardiography confirms and which is repaired surgically, timed to the patient's stability.

Sources: Bootsma et al., PA Catheter Part 2 (2022); Merck Manual, Professional Version

Question 7 · Hemodynamics

A patient on a cardiac step-down unit after GI bleeding has an ScvO₂ of 55%, hemoglobin 6.8 g/dL, SaO₂ 96% on 2 L, CI 2.7 L/min/m², and lactate 2.6 mmol/L. The patient is calm, afebrile, and not shivering. Which intervention will MOST effectively improve oxygen delivery?

  1. Start dobutamine to increase cardiac output
  2. Apply higher PEEP through noninvasive ventilation
  3. Transfuse packed red blood cells
  4. Increase the FiO₂ to raise the SaO₂ to 100%
Show the answer and rationale

Answer: C

  • A. Cardiac output is adequate, and inotropes increase myocardial oxygen demand.
  • B. Oxygenation is adequate, and PEEP would not correct the reduced carrying capacity.
  • C. Correct. Hemoglobin is the limiting factor in oxygen content here. Raising it improves oxygen delivery the most.
  • D. With SaO₂ already 96%, more oxygen adds very little to arterial oxygen content.

Oxygen delivery = CO × CaO₂, where CaO₂ ≈ 1.34 × Hgb × SaO₂ (plus a small dissolved fraction). A normal ScvO₂ is about 70% or higher. A low value means delivery is falling short of demand. With adequate CI and SaO₂, the most affected variable is hemoglobin, which is roughly half of normal. Transfusion is appropriate here given the ongoing bleeding and evidence of inadequate delivery (low ScvO₂, elevated lactate), and a threshold around 8 g/dL is often used for patients with cardiovascular disease.

Sources: Lough, Hemodynamic Monitoring (2015); AABB RBC Transfusion Guidelines (2023)

Question 8 · Hemodynamics

A patient's central venous pressure has read 6 to 7 mm Hg all morning. The bed was just raised about 10 cm (4 inches) for a dressing change, and the transducers on the IV pole were not moved. The central venous pressure now reads 14 mm Hg, and the arterial pressure reads 132/74 mm Hg, up from 124/66 mm Hg. Heart rate, SpO₂, breath sounds and urine output are unchanged, and no fluid has been given. Which explanation is MOST likely?

  1. Drift in the transducers' zero reference since setup
  2. Transducers now above the level of the phlebostatic axis
  3. Transducers now below the level of the patient's heart
  4. Rising right-sided filling pressure from fluid overload
Show the answer and rationale

Answer: C

  • A. Zeroing to air removes atmospheric pressure and is repeated when values do not fit the patient, but a shift that appears on two lines at once, exactly when the bed height changed, points to leveling.
  • B. Transducers above the axis read falsely low, the opposite of the change seen; this would happen if the bed were lowered under a fixed transducer.
  • C. Correct. Raising the bed lifted the phlebostatic axis above the fixed transducers, adding hydrostatic pressure of about 2 mm Hg per inch, roughly 8 mm Hg here, to every line mounted at that height.
  • D. Volume overload can raise the central venous pressure, but no fluid was given, the other findings are unchanged, and the arterial pressure rose by the same amount at the moment the bed moved.

Pressure transducers read relative to the height of their zeroing stopcock, so the stopcock is leveled to the phlebostatic axis, the fourth intercostal space midway between the front and back of the chest. For every inch (2.5 cm) that the heart sits above the transducer, about 2 mm Hg of hydrostatic pressure is added and the reading is falsely high; a heart below the transducer reads falsely low. An 8 mm Hg error barely matters against a mean arterial pressure near 90 but doubles a central venous pressure of 7, which could lead to fluid being withheld. Pole-mounted transducers are re-leveled after every change in bed height, with a carpenter's or laser level rather than by eye.

Sources: Edwards Cardiopulmonary Quick Guide, 4th ed.

Question 9 · Undifferentiated Shock

A patient in cardiogenic shock from an acute MI has CO 2.5 L/min, MAP 50 mm Hg, and CVP 15 mm Hg. What is the SVR, and how should it be interpreted?

  1. 1,120; elevated, the expected compensation
  2. 1,120; normal, but inappropriately low here
  3. 1,680; elevated, the expected compensation
  4. 560; low, consistent with septic shock
Show the answer and rationale

Answer: B

  • A. An SVR of 1,120 falls in the normal range (about 800–1,200), not the elevated range.
  • B. Correct. Cardiogenic shock usually causes intense vasoconstriction. A normal SVR suggests a mixed vasodilatory (inflammatory) component.
  • C. This is a calculation error. The correct value is 80 × 35 ÷ 2.5 = 1,120.
  • D. This is a calculation error, and the value is not low.

SVR = 80 × (MAP − CVP) ÷ CO = 80 × 35 ÷ 2.5 = 1,120 dynes·sec/cm⁻⁵. In classic cardiogenic shock, the SVR is high. The SHOCK trial showed that about one in five patients with MI-related cardiogenic shock develop a systemic inflammatory response with inappropriate vasodilation, and sepsis can also coexist. Recognizing a mixed profile supports adding a vasopressor such as norepinephrine alongside inotropic or mechanical support, and prompts a search for infection.

Sources: Lough, Hemodynamic Monitoring (2015); AACN Essentials of Critical Care, 5th ed.; Edwards Cardiopulmonary Quick Guide, 4th ed.

Question 10 · Hemodynamics

A ventilated patient’s mixed venous oxygen saturation falls from 72% to 51% in an hour while the SpO₂ stays at 96% and the hemoglobin is stable at 11 g/dL. What is the most likely explanation?

  1. The catheter has wedged, which always lowers the reading
  2. Cardiac output has fallen or oxygen consumption has risen
  3. The arterial oxygen content has dropped because of anemia
  4. Oxygen delivery has improved, so the tissues extract less
Show the answer and rationale

Answer: B

  • A. A wedged catheter samples arterialized blood and reads falsely high.
  • B. Correct. With arterial saturation and hemoglobin unchanged, more extraction means that delivery has dropped through a lower output or that demand has risen with fever, shivering or agitation.
  • C. The hemoglobin and SpO₂ are unchanged.
  • D. Better delivery would raise the venous saturation.

Mixed venous saturation (normally 60% to 80%) reflects the balance of oxygen delivery and consumption. It falls with a low cardiac output, anemia, hypoxemia or increased demand, and it is high in sepsis, with left-to-right shunts and with a wedged catheter. A value under 50% signals inadequate delivery.

Sources: Wilkins' Clinical Assessment in RC, 10th ed.; Egan's Fundamentals of Resp Care, 13th ed.

Practice this in the app

These 10 are a sample. ICU Basics has 71 hemodynamics questions, and it keeps your score, explains every choice and brings back the ones you miss. No ads. Pro is coming in January 2027.

Practice 71 questions in your browser

Download on theApp StoreGet it onGoogle Play

Study the topic

More practice questions

Sample questions by exam