Hemodynamics
Systemic Vascular Resistance (SVR) Calculator
Afterload of the left ventricle from MAP, CVP and cardiac output; low in vasodilatory shock, high in cardiogenic and hypovolemic shock.
Formula
SVR = (MAP - CVP) / CO × 80
Reference: Normal 800–1200
How it is used
- Normal SVR is 800–1200 dyn·s/cm⁵.
- Low SVR: vasodilatory (distributive) shock, such as sepsis, anaphylaxis or neurogenic shock.
- High SVR: compensatory vasoconstriction in cardiogenic or hypovolemic shock; check the filling pressures to tell them apart.
Related one-pagers
- Hemodynamic NormalsSVR · 800–1200 · dyn·s/cm⁵
- Shock Types at a GlanceSVR · 1,490 · 1,370 · 500 · 1,230 · 1,200
- Swan-Ganz (PA Catheter): Waveforms, Wedge and Normal ValuesSVR · 800–1200 dyn·s/cm⁵ · (MAP − CVP) × 80 ÷ CO
- Sepsis and Septic Shock BundleSVR · Normal or high · Low (<800 dyn·s·cm⁻⁵)
Related calculators
- Cardiac Index (CI)
- Cardiac Output (Fick Principle)
- Cardiac Output (HR × SV)
- Cerebral Perfusion Pressure (CPP)
- Coronary Perfusion Pressure
- Ejection Fraction (EF)
- Mean Arterial Pressure (MAP)
- Oxygen Delivery (DO₂)
Practice free in your browser3,800+ exam-style questions with rationales. No account, no ads. Also free on the App Store and Google Play.
For education and exam preparation only. Follow your institution’s protocols. For education and exam preparation only. Verify results independently and follow your institution’s protocols. Not a substitute for clinical judgment.